Our Lab

This page lists the hardware which is available for testing HelenOS and is within the reach of some HelenOS developer.

Per processor architecture

Architecture Product name HelenOS contact Current status Working release Comments
amd64/ia32 AMD Phenom Triple, ASUSTeK M3N WS MD unknown 0.4.2 (1)
amd64/ia32 Apple Mac Pro 4.1 (Early 2009) MD unknown 0.4.2 (1)
amd64/ia32 Intel Core 2 Quad (2x), Intel S5000XVNSATAR MD working mainline (r992)
arm32 Neo FreeRunner JS, JJ, VP working mainline HelenOS on Neo FreeRunner
arm32 HP iPAQ H5500 MD unsupported
ia32 ThinkPad T60 MD working mainline (r992)
ia32 Intel Pentium 4 (HT) JJ unknown 0.2.0
ia32 Intel Pentium Dual-Core CPU E5200, Fujitsu Esprimo P2540 JJ working mainline (2)
ia32 AMD Phenom II X6 1090T JJ partially working mainline
ia64 Dell PowerEdge 3250 JJ, JV partially working 0.4.0 (3), Service Tag: CMN8W31
ia64 Dell PowerEdge 7150 MD unsupported
mips32 Ben NanoNote MD unsupported
mips64 Sgi Octane (IP30) MD unsupported
mips64 Lemote Fuloong MD unsupported
ppc32 Apple iBook G4 (Mid 2005) JJ none 0.4.1 Seems to be dead
ppc32 Apple iMac G4 (Flat Panel) MD working mainline (r992) (4)
ppc64 Apple iMac G5 (Ambient Light Sensor) MD unsupported
sparc32 LEON3 on Hpe-mini LEC2 FPGA board MD unsupported
sparc64 Sun Ultra 60 MD not working 0.4.3 #345
sparc64 Sun SPARC Enterprise T1000 MD not working 0.4.2 #324, prtconf -pv

Comments

  1. Wrong number of CPUs detected, issues related to #248 (a keypress is needed), timer running too slow.
  2. Too slow clock in absence of any load. When multiple tester loop1 instances ran, clock seemed to be OK.
  3. Reaches bdsh when image.boot loaded by elilo, by chance.
  4. Boots OK, but unusable due to USB-only HID.

Legend of the Working release field

  • mainline (revision) = HelenOS is being regularly tested on the given machine as part of the current development efforts, thus the machine should be supported in the next stable release. The latest mainline Bazaar revision should be appended in the brackets.
  • none = HelenOS was never actually tested on the given machine, but it is reasonable to believe that the probability of HelenOS working flawlessly on the machine is high (due to similarity to other supported machines).
  • unsupported = The given machine is currently unsupported because of some fundamental reason (i.e. the hardware architecture is out of the scope of the current HelenOS development efforts).
  • specific version = HelenOS did support the given machine in the past, but the support has been since broken, usually due to some fundamental changes which were not debugged on the given machine so far.

Legend of the Current status field

  • working = Almost all features of the indicated release are supported on the machine.
  • partially working = The indicated release is more-or-less supported on the machine, but with some glitches or limitations indicated.
  • unknown = The machine was working in the release indicated, but it has not been tested for a while.
  • not working = Although the machine should be supported, it has some major problems.
  • empty status = Unsupported machine.